Private report
Revasive/Sample inspection

Residential property inspection

1428 Alder Street

Portland, Oregon 97214

Inspection date
June 18, 2026
Report no.
HHI-260618-042
Prepared for
Jordan & Taylor Morgan
DM
Prepared byDaniel Morris, CPIHearth & Home Inspections ยท OR CCB #248193
Contact inspector

Inspection summary

Overall condition

This home was observed to be in generally serviceable condition for its age. The items below should be reviewed with the appropriate qualified professionals before the end of the inspection contingency period.

23Systems reviewed
3Repair items
4Maintenance items
!
Priority items

Roof flashing, electrical panel clearance, and active moisture below the kitchen sink merit prompt evaluation.

Area 01

Exterior & roof

Roofing, drainage, siding, grading, walkways, and attached structures.

2 findings
Interactive 3D modelUse mouse or touch to explore
Finding EX-01Repair recommended

Open seam at roof flashing

Observation An open seam was observed in the metal flashing above the east roof slope near the chimney transition.

Why it matters Open flashing joints can allow water intrusion and damage concealed roof components.

Recommendation Have a qualified roofing contractor evaluate and repair the flashing before closing.

Location: East roof slopeView point in 3D
Finding EX-02Maintenance

Debris in north gutter

Recommendation Clean the gutter and confirm downspout flow as part of routine seasonal maintenance.

Location: North elevationView point in 3D

Area 02

Interior living areas

Walls, ceilings, floors, windows, doors, stairs, and installed fixtures.

1 finding
Interactive 3D modelUse mouse or touch to explore
Finding IN-01Monitor

Minor settlement crack

Observation A narrow diagonal drywall crack was visible above the southeast bedroom door.

Recommendation Monitor for change. Seek further evaluation if the crack widens, reappears after repair, or door operation changes.

Location: Southeast bedroomView point in 3D

Area 03

Major systems

Electrical, plumbing, heating, cooling, water heating, and visible distribution components.

2 findings
Interactive 3D modelUse mouse or touch to explore
Finding SY-01Repair recommended

Restricted panel working clearance

Recommendation Relocate stored materials and maintain clear working space in front of the electrical panel.

Location: Garage west wallView point in 3D
Finding SY-02Repair recommended

Active moisture below sink

Recommendation Have a qualified plumbing contractor identify the source, repair the leak, and evaluate affected cabinet materials.

Location: Kitchen sink cabinetView point in 3D

Report information

Scope & limitations

This sample report demonstrates the Revasive delivery format. A home inspection is a visual, non-invasive examination of readily accessible systems and components at the time of inspection.